BWLGS - LITHO FILM A557

  • MSDS: BWLGS
  • Manufacturer: ANITEC IMAGE CORP
  • Product Name: LITHO FILM A557
  • National Stock Number: 6750-01-227-4187
Product Identification

Product ID:LITHO FILM A557
MSDS Date:10/01/1989
FSC:6750
NIIN:01-227-4187
MSDS Number: BWLGS

Responsible Party
ANITEC IMAGE CORP
40 CHARLES ST
BINGHAMTON, NY 13902
US

Emergency Phone: 607-774-3333

Info Phone: 800-234-7707

Cage: 61263

Contractor
ANITEC IMAGE CORP
4444 BINGHAMTON, NY 13902 US

Telephone: 607-774-3333

Cage: 61263

Ingredients

CELLULOSE TRIACETATE

CAS: 9012-09-3

Fraction By Weight: >90%


GELATIN


SILVER CHLORIDE

CAS: 7783-90-6

RTECS: VW3563000


SILVER HALIDES

CAS: 7783-96-2


CADMIUM CHLORIDE (SARA III)

CAS: 10108-64-2

RTECS: EV0175000

Fraction By Weight: TRACE

OSHA PEL 0.2 MG (CD)/M3 DUST

ACGIH TLV: 0.01 MG(CD)/M3; 9394

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


SILVER BROMIDE

CAS: 7785-23-1

Hazards

LD50 LC50 Mixture:NOT GIVEN FOR PRODUCT AS A WHOLE
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:THIS PRODUCT CONTAINS SMALL AMOUNTS OF
A CADMIUM SALT AND MAY CAUSE LOCALIZED IRRITATION. CADMIUM HAS BEEN
DETERMINED TO BE A CARCINOGEN BASED ON SUBCUTANEOUS AMINAL LAB
STUDIES. CARE SHOULD BE TAKEN TO MINIMIZE EXPOSURE TO SOLUTIONS IN
WHICH THIS PRODUCT HAS BEEN PROCESSED.
Explanation of Carcinogenicity:PRODUCT CONTAINS A SMALL AMOUNT OF
CADMIUM WHICH IARC HAS DEFINED AS A CARCINOGEN OR SUSPECT
CARCINOGEN.
Effects of Overexposure:NONE KNOWN TO MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:REMOVE FROM SOURCE OF EXPOSURE. WASH AFFECTED AREAS
THOROUGHLY. IF IRRITATION OR OTHER CONDITIONS PERSIST, CONSULT A
PHYSICIAN.

Fire Fighting

Flash Point:NONFLAMMABLE
Lower Limits:NOT GIVEN
Upper Limits:NOT GIVEN
Extinguishing Media:WATER MIST, ALCOHOL FOAM, CARBON DIOXIDE, DRY
CHEMICAL
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE.
Unusual Fire/Explosion Hazard:AVOID BREATHING COMBUSTIBLE FUMES.

Accidental Release

Spill Release Procedures:COLLECT SPILLED MATERIAL FOR DISPOSAL. UNUSED
FILM MAY BE REPACKAGED FOR FUTURE USE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN A COOL, DRY PLACE AWAY FROM
HEAT, RADIATION OR LIGHT SOURCES.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NOT NORMALLY REQUIRED.
Ventilation:NOT NORMALLY REQUIRED.
Protective Gloves:DISPOSABLE COTTON RECOMMENDED
Eye Protection:NOT NORMALLY REQUIRED.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH WITH SOAP AND WATER AFTER HANDLING PRODUCT
AND BEFORE EATING DRINKING OR SMOKING.
Supplemental Safety and Health
NOTE TO PRODUCT SOLUBILITY: PRODUCT IS ESSENTIALLY INSOLUBLE, EXCEPT
FOR CADMIUM SALTS AND OTHER TRACE COMPONENTS IN GELATIN MATRIX.

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:NOT GIVEN
Melt/Freeze Pt:M.P/F.P Text:NOT GIVEN
Vapor Pres:NEGLIGIBLE
Vapor Density:NEGLIGIBLE
Spec Gravity:NOT GIVEN
Evaporation Rate & Reference:NEGLIGIBLE
Solubility in Water:INSOLUBLE
Appearance and Odor:GREY EMULSION COATED FILM WITH NO DISTINGUISHING
ODOR

Stability

Stability Indicator/Materials to Avoid:YES
DO NOT IMMERSE IN WATER OR CHEMICALS PRIOR TO PROCESSING.
Stability Condition to Avoid:HEAT, LIGHT AND OTHER RADIATION SOURCES
EXCEPT AS NECESSARY TO PROCESS
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

Disposal

Waste Disposal Methods:DISCARD ANY PRODUCT, RESIDUE, DISPOSAL CONTAINER
OR LINER IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.